Back to articles

Galfan and hot-dip zinc: an engineering procurement guide to gabion corrosion protection

Compare metallic and polymer coating systems through exposure, material identification, handling damage and inspection evidence.

1. Define the exposure before choosing a coating

The product name alone does not identify a suitable corrosion-protection system. Record whether the installation is in fresh water, a coastal splash zone, saline soil, an industrial watercourse or another aggressive environment. Include wet/dry cycling, sediment abrasion, sunlight, temperature and the possibility of damage during filling. A buried wall and a periodically submerged revetment can have different controlling conditions even when their mesh dimensions are identical.

The design brief should also identify how the structure will be inspected and repaired. A coating that can tolerate the expected environment still needs compatible connections, suitable stone and careful installation. Damage at a cut end, fastener or heavily abraded contact can matter more than an isolated laboratory comparison of intact wires.

2. Separate the metallic coating from an optional polymer sheath

Hot-dip zinc and zinc–aluminium alloy coatings must be specified by composition, coating mass, wire size and the applicable material requirements. The word “Galfan” should not substitute for an inspection record. Where a polymer overcoat is required, identify the actual compound, thickness and test requirements separately. PVC and PA6 are different materials and their chemical or abrasion results are not interchangeable.

Procurement fieldWhat the buyer should receive
Base wireNominal diameter, tensile requirements and traceable batch
Metallic coatingAlloy designation, required coating mass and inspection method
Polymer overcoatActual polymer, nominal thickness, adhesion and relevant durability evidence
Lacing and fastenersMaterial and coating compatibility with the mesh
Handling protectionPacking, lifting and repairs for damaged coating

3. Read the standard and the report as different documents

ASTM A975 and EN 10223-3 can be discussed as specification references for appropriate double-twisted mesh products. The applicable edition, coating designation and ordered configuration should be stated in the contract. A reference to a standard in an article is not evidence that a particular shipment has passed every applicable test.

An inspection report should identify the tested product, wire diameter, coating and sample batch. A result for another manufacturer’s proprietary system or a different polymer cannot be transferred to an offered Zhongman product merely because both are described as coated gabions. Ask which requirements the inspection document actually covers and which remain subject to project testing.

4. Do not convert salt-spray hours into a field-life promise

Accelerated testing is useful for comparing specified specimens under a defined method. It does not directly establish a universal number of years in a river, coastal splash zone or soil. Field performance also depends on abrasion, defects, water chemistry, oxygen availability and the detailed connection system. Avoid fixed service-life multipliers or unconditional 50-year and 100-year guarantees without a project-specific basis.

5. Inspect the coating during installation

  1. Check labels and packing before unloading; retain the link between delivered bundles and inspection records.
  2. Use suitable lifting arrangements and remove sharp protrusions from the prepared base.
  3. Assemble and connect units using the approved lacing or fastener system.
  4. Control stone placement to avoid cutting the polymer or distorting the mesh.
  5. Record exposed steel, damaged sheath, poor closure and repairs before the works are covered.

6. Engineering FAQ

Q1: Is zinc–aluminium always the correct choice?

No single coating is automatically correct for every environment. Compare the exposure, coating specification, connection details and available inspection evidence before selecting a system.

Q2: Does a polymer coating remove the need to inspect the metallic coating?

No. A dual-layer system still needs the specified substrate and compatible connection materials. The polymer layer does not make damage, cuts or unsuitable fasteners irrelevant.

Q3: Does a salt-spray test prove a fixed service life?

No. It records performance under its stated test conditions. Any field-life assessment must address the actual exposure and configuration.

Explore gabion products · Discuss the project specification